Emission Reduction

Emission Rx Enclosed Combustor: E-Series

Beneficial

Meets CSA Z620.3 requirements

Proven

Emission Rx units are proven to have
99.9% combustion efficiency

Easy

Easy to install & easy to operate

Emission Rx Enclosed Combustor

Emission Rx Enclosed Combustors provide high-performance combustion in a compact, affordable design. The E-Series utilizes proprietary technology to achieve maximum airflow to the combustion chamber while simultaneously reducing the outer shell temperature.

  • Preheat inlet air to further improve combustion efficiencies
  • High flow inlet air for optimal oxygen mixing ratios
  • Cool outer shell to eliminate burn hazards or potential for igniting organic material that may       settle near the combustor
  • Wide range of operating pressures
  • No visible flame, smoke or odour
  • Concrete base included (self supporting, no guy required)
  • Industry leading Profire Burner Management System
  • All components, including pilot, are easily accessible
  • Continuous pilot or direct spark operation
  • SCADA compatible
  • Quiet operation – 65 to 80 decibels at 1 metre
  • Intake air and inline fuel gas flame arresting devices

Flow rates from 0.2 e3m3/d (7 mscf/d) to 20 e3m3/d (700 mscf/d)

(see specification chart for more details)
Model No.
Size
Capacity
Methane Equivalent Flow Rate
Electrical
Close Spacing Eligible
Self Supporting
Exit Temperature Monitoring
Easy Operator Controls
Model No.
Diameter x Height (ft)
(MMBTU/hr)
(e3m3/d [mscf/d])
Electrical
(10 Meters)
(Concrete Base)
Exit Temperature Monitoring
Easy Operator Controls
E 24-12 (HP/LP)
24"/12" x 12'
0.3
0.2[17]
12V / 24V
E 36-12 (HP/LP)
36"/24" x 12'
1
0.7[25]
12V / 24V
E 48-12 (HP/LP)
48"/36" x 12'
2.4
1.6[57]
12V / 24V
E 60-12 (HP/LP)
60"/48" x 12'
3.7
2.5[88]
12V / 24V
E 72-12 (HP/LP)
72"/53" x 12'
5
3.5[106]
12V / 24V
E 96-12 (HP/LP)
96"/72" x 12'
7.4
5[175]
12V / 24V
E 96-24 (HP)
96"/72" x 24'
15
10 [352]
12V / 24V
E 120-24 (HP)
120"/80" x 24'
30
20[710]
12V / 24V

**Please contact us for custom waste gas volumes greater than identified in the above table

(HP/LP) High-Pressure/Low-Pressure. High-Pressure is considered anything >1psi and Low-Pressure is anything <1psi

Low-Pressure applications can have a reduced capacity. Please contact for more information.

Emission Rx EF-Series

Useful

Helps meet government GHG reduction regulations

Proven

Emission Rx units are proven to have
99.9% combustion efficiency

Easy

Easy to install & easy to operate

Emission Rx EF-Series

Emission Rx EF-Series provide high-performance combustion in an extremely affordable design. The EF-Series utilizes proprietary technology to handle high flow capacity without the typical problems of a standard flare.

  • High flow inlet air for optimal oxygen mixing ratios
  • Wide range of operating pressures
  • No visible flame, smoke or odour
  • Concrete base included (self supporting, no guy required)
  • Industry leading Profire Burner Management System
  • All components, including pilot, are easily accessible
  • Continuous pilot or direct spark operation
  • SCADA compatible
  • Low noise operation
  • Inline fuel gas flame arrestor

%

combustion efficiency at any pressure

Flow rates from 5.0 e3m3/d (175 mscf/d) to 30 e3m3/d (1060 mscf/d)

(see specification chart for more details)
Model No.
Size
Capacity
Methane Equivalent Flow Rate
Electrical
Close Spacing Eligible
Self Supporting
Exit Temperature Monitoring
Easy Operator Controls
Model No.
Diameter x Height (ft)
(MMBTU/hr)
(e3m3/d [mscf/d])
Electrical
(10 Meters)
(Concrete Base)
Exit Temperature Monitoring
Easy Operator Controls
E 24-12 (HP/LP)
24"/12" x 12'
0.3
0.2[17]
12V / 24V
E 36-12 (HP/LP)
36"/24" x 12'
1
0.7[25]
12V / 24V
E 48-12 (HP/LP)
48"/36" x 12'
2.4
1.6[57]
12V / 24V
E 60-12 (HP/LP)
60"/48" x 12'
3.7
2.5[88]
12V / 24V
E 72-12 (HP/LP)
72"/53" x 12'
5
3.5[106]
12V / 24V
E 96-12 (HP/LP)
96"/72" x 12'
7.4
5[175]
12V / 24V
E 96-24 (HP)
96"/72" x 24'
15
10 [352]
12V / 24V
E 120-24 (HP)
120"/80" x 24'
30
20[710]
12V / 24V

**Please contact us for custom waste gas volumes greater than identified in the above table

(HP/LP) High-Pressure/Low-Pressure. High-Pressure is considered anything >1psi and Low-Pressure is anything <1psi

Low-Pressure applications can have a reduced capacity. Please contact for more information.

Model No.
Size
Capacity
Methane Equivalent Flow Rate
Electrical
Close Spacing Eligible
Self Supporting
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
Model No.
Diameter x Height (ft)
(MMBTU/hr)
(e3m3/d [mscf/d])
Electrical
(10 Meters)
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
EF 24-14
2' x 14'
1.9
1.25 [44]
12V / 24V
EF 24-25
2' x 25'
3.7
2.5 [88]
12V / 24V
EF 36-14
3' x 14'
4
2.7 [95]
12V / 24V
EF 36-24
3' x 24'
8.2
5.5 [194]
12V / 24V
EF 48-24
4' x 24'
15
10 [353]
12V / 24V

Emission Rx Direct Fired Thermal Oxidizer (DFTO)

 

Opportunity

Meets government air
quality objectives

Proven

Emission Rx units are proven to have
99.9% combustion efficiency

Discover

Easy to install, easy to
operate and very reliable

Emission Rx ERF Series Direct Fired
Thermal Oxidizer (DFTO)

Emission Rx Direct Fired Thermal Oxidizers provide high-performance destruction of VOC’s in an affordable design. Hydrocarbons, solvent fumes, halogenated hydrocarbons, hazardous air pollutants (HAPS), or other odour producing compounds are destroyed with 99.9% combustion efficiency.

  • Small footprint, self supported
  • High flow inlet air for optimal oxygen mixing ratios
  • Wide range of operating pressures
  • No visible flame, smoke or odour (>99.9% combustion efficiency)
  • Exhaust stack uses high temperature refractory insulation
  • Combustion and exhaust temperature control and monitoring
  • Industry leading Profire™ Burner Management System (BMS)
  • SCADA compatible
  • Heat recovery options available
  • Modulated burner controls for optimum performance in fluctuating flow & composition
  • Burner manifold designed for corrosive environments
  • CSA 149.3 compliant fuel system
  • Operator safe design
  • Low maintenance, no moving parts
  • Fuel consumptions and mass balance available on a case by case basis

%

combustion efficiency at any pressure

Model No.
Size
Capacity
Methane Equivalent Flow Rate
Electrical
Close Spacing Eligible
Self Supporting
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
Model No.
Diameter x Height (ft)
(MMBTU/hr)
(e3m3/d [mscf/d])
Electrical
(10 Meters)
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
EF 24-14
2' x 14'
1.9
1.25 [44]
12V / 24V
EF 24-25
2' x 25'
3.7
2.5 [88]
12V / 24V
EF 36-14
3' x 14'
4
2.7 [95]
12V / 24V
EF 36-24
3' x 24'
8.2
5.5 [194]
12V / 24V
EF 48-24
4' x 24'
15
10 [353]
12V / 24V
Model No.
Size
Capacity
Methane Equivalent Flow Rate
Electrical
Close Spacing Eligible
Self Supporting
Exit Temperature Monitoring
Easy Operator Controls
Model No.
Diameter x Height (ft)
(MMBTU/hr)
(e3m3/d [mscf/d])
Electrical
(10 Meters)
(Concrete Base)
Exit Temperature Monitoring
Easy Operator Controls
E 24-12 (HP/LP)
24"/12" x 12'
0.3
0.2[17]
12V / 24V
E 36-12 (HP/LP)
36"/24" x 12'
1
0.7[25]
12V / 24V
E 48-12 (HP/LP)
48"/36" x 12'
2.4
1.6[57]
12V / 24V
E 60-12 (HP/LP)
60"/48" x 12'
3.7
2.5[88]
12V / 24V
E 72-12 (HP/LP)
72"/53" x 12'
5
3.5[106]
12V / 24V
E 96-12 (HP/LP)
96"/72" x 12'
7.4
5[175]
12V / 24V
E 96-24 (HP)
96"/72" x 24'
15
10 [352]
12V / 24V
E 120-24 (HP)
120"/80" x 24'
30
20[710]
12V / 24V

**Please contact us for custom waste gas volumes greater than identified in the above table

(HP/LP) High-Pressure/Low-Pressure. High-Pressure is considered anything >1psi and Low-Pressure is anything <1psi

Low-Pressure applications can have a reduced capacity. Please contact for more information.

Model No.
Size
Capacity
Methane Equivalent Flow Rate
Electrical
Close Spacing Eligible
Self Supporting
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
Model No.
Diameter x Height (ft)
(MMBTU/hr)
(e3m3/d [mscf/d])
Electrical
(10 Meters)
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
EF 24-14
2' x 14'
1.9
1.25 [44]
12V / 24V
EF 24-25
2' x 25'
3.7
2.5 [88]
12V / 24V
EF 36-14
3' x 14'
4
2.7 [95]
12V / 24V
EF 36-24
3' x 24'
8.2
5.5 [194]
12V / 24V
EF 48-24
4' x 24'
15
10 [353]
12V / 24V

Emission Rx C-Series Incinerator

Safe Destruction of Sour Gas, Trace Vent Gas or other Harmful Gases

Opportunity

Meets government air
quality objectives

Proven

Emission Rx units are proven to have
99.9% combustion efficiency

Discover

Easy to install, easy to
operate and very reliable

Emission Rx Incinerator safely destroy harmful gases and meet or exceed government air quality objectives.

Emission Rx Incinerators are temperature controlled and engineered to provide high performance destruction of VOC’s, including BTEX, H2S and other hazardous air pollutants.

  • Small footprint, self supported
  • High flow inlet air for optimal oxygen mixing ratios
  • Wide range of operating pressures
  • No visible flame, smoke or odour (>99.9% combustion efficiency)
  • Insulated and cladded exhaust stack
  • Combustion and exhaust temperature control and monitoring
  • Industry leading Profire™ Burner Management System (BMS)
  • SCADA compatible
  • Burner manifold designed for corrosive environments
  • CSA 149.3 compliant fuel system
  • Operator safe design
  • Low maintenance, no moving parts
  • Fuel consumptions and mass balance available on a case by case basis
  • Intake air and inline fuel gas flame arrestors
Model No.
Size
Capacity
Methane Equivalent Flow Rate
Electrical
Close Spacing Eligible
Self Supporting
Exit Temperature Monitoring
Easy Operator Controls
Model No.
Diameter x Height (ft)
(MMBTU/hr)
(e3m3/d [mscf/d])
Electrical
(10 Meters)
(Concrete Base)
Exit Temperature Monitoring
Easy Operator Controls
E 24-12 (HP/LP)
24"/12" x 12'
0.3
0.2[17]
12V / 24V
E 36-12 (HP/LP)
36"/24" x 12'
1
0.7[25]
12V / 24V
E 48-12 (HP/LP)
48"/36" x 12'
2.4
1.6[57]
12V / 24V
E 60-12 (HP/LP)
60"/48" x 12'
3.7
2.5[88]
12V / 24V
E 72-12 (HP/LP)
72"/53" x 12'
5
3.5[106]
12V / 24V
E 96-12 (HP/LP)
96"/72" x 12'
7.4
5[175]
12V / 24V
E 96-24 (HP)
96"/72" x 24'
15
10 [352]
12V / 24V
E 120-24 (HP)
120"/80" x 24'
30
20[710]
12V / 24V

**Please contact us for custom waste gas volumes greater than identified in the above table

(HP/LP) High-Pressure/Low-Pressure. High-Pressure is considered anything >1psi and Low-Pressure is anything <1psi

Low-Pressure applications can have a reduced capacity. Please contact for more information.

Model No.
Size
Capacity
Methane Equivalent Flow Rate
Electrical
Close Spacing Eligible
Self Supporting
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
Model No.
Diameter x Height (ft)
(MMBTU/hr)
(e3m3/d [mscf/d])
Electrical
(10 Meters)
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
EF 24-14
2' x 14'
1.9
1.25 [44]
12V / 24V
EF 24-25
2' x 25'
3.7
2.5 [88]
12V / 24V
EF 36-14
3' x 14'
4
2.7 [95]
12V / 24V
EF 36-24
3' x 24'
8.2
5.5 [194]
12V / 24V
EF 48-24
4' x 24'
15
10 [353]
12V / 24V

Etter Engineering Catalytic Methane Abatement System (CMAS)

Useful

Helps meet government GHG reduction regulations

Proven

Etter units are proven to have efficiency greater than 85%

Easy

Easy to install, and easy to
operate

Etter Eng. CMAS System

The patented Catalytic Methane Abatement System (CMAS) by ETTER Engineering utilizes a platinum based catalyst to convert methane into CO2 and water vapour. These units are designed for outdoor installation, operate indefinitely without on-site electrical power, and utilize CSA components for Class I, Division I installations. CMAS is delivered as a complete “Plug & Play” assembly, leading the way in mitigating methane’s impact on our climate.

  • Available in sizes: S, M, L, & XL
  • Fabricated metal housing for protection from the elements
  • Capacity can be increased with multi-unit configurations
  • Utilizes components that are CSA approved for Class I Division II
  • Unit is provided as a complete “Plug-and-Play”
  • P.Eng stamped as intrinsically safe for positioning on wellsite
  • Low noise operation
  • Heater startup power cords included
Model No.
Size
Capacity
Methane Equivalent Flow Rate
Electrical
Close Spacing Eligible
Self Supporting
Exit Temperature Monitoring
Easy Operator Controls
Model No.
Diameter x Height (ft)
(MMBTU/hr)
(e3m3/d [mscf/d])
Electrical
(10 Meters)
(Concrete Base)
Exit Temperature Monitoring
Easy Operator Controls
E 24-12 (HP/LP)
24"/12" x 12'
0.3
0.2[17]
12V / 24V
E 36-12 (HP/LP)
36"/24" x 12'
1
0.7[25]
12V / 24V
E 48-12 (HP/LP)
48"/36" x 12'
2.4
1.6[57]
12V / 24V
E 60-12 (HP/LP)
60"/48" x 12'
3.7
2.5[88]
12V / 24V
E 72-12 (HP/LP)
72"/53" x 12'
5
3.5[106]
12V / 24V
E 96-12 (HP/LP)
96"/72" x 12'
7.4
5[175]
12V / 24V
E 96-24 (HP)
96"/72" x 24'
15
10 [352]
12V / 24V
E 120-24 (HP)
120"/80" x 24'
30
20[710]
12V / 24V

**Please contact us for custom waste gas volumes greater than identified in the above table

(HP/LP) High-Pressure/Low-Pressure. High-Pressure is considered anything >1psi and Low-Pressure is anything <1psi

Low-Pressure applications can have a reduced capacity. Please contact for more information.

Model No.
Size
Capacity
Methane Equivalent Flow Rate
Electrical
Close Spacing Eligible
Self Supporting
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
Model No.
Diameter x Height (ft)
(MMBTU/hr)
(e3m3/d [mscf/d])
Electrical
(10 Meters)
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
EF 24-14
2' x 14'
1.9
1.25 [44]
12V / 24V
EF 24-25
2' x 25'
3.7
2.5 [88]
12V / 24V
EF 36-14
3' x 14'
4
2.7 [95]
12V / 24V
EF 36-24
3' x 24'
8.2
5.5 [194]
12V / 24V
EF 48-24
4' x 24'
15
10 [353]
12V / 24V

Ready to Upgrade Your Operation?

Need help selecting the right product? Our team is available to guide you through site-specific and regulatory requirements. Submit the form below and we’ll be in touch shortly.

6 + 11 =