Every Flare, Incinerator or Combustor needs liquid separation to eliminate high energy liquids from entering the combustion device and causing a hazardous operational situation.
The piece of equipment used for liquid separation, in this scenario, is commonly referred to as a Knock Out Drum (KOD), formerly called an FKOD (flare knock out drum). A KOD can be anything from a small fuel gas scrubber (6” diameter) up to a large vessel (8’ diameter).
The design of a KOD is determined by several important factors.
- Can it remove the majority of the large liquid droplets? The KOD should be capable of eliminating droplets with a size between 300-600 microns (AER, Directive 60).
- Can it handle the volume of liquids it may encounter (holding capacity) based on the site conditions? For example, a tank vent may have a higher volume of condensation, resulting in increased liquids to the KOD. The KOD will need to be sized to accommodate these higher liquid volumes.
![]()
Design Considerations
Manufacturers of KOD’s use a variety of different design techniques to achieve these results. Here are a few design considerations to look for when purchasing a KOD.
- Does it have an inlet device to reduce the velocity of the gases? Reduced velocity will help liquids to drop.
- Is there a section where the gas will move at a relatively low velocity to encourage further separation (Gas Gravity Section)?
- Is there a section where the liquids receive any liquids dropping out (Liquid Gravity Section)? This liquid also degases as it sits in the KOD.
- Does it have a mist extractor? Mist extractors can help further remove liquids and polishing the gas. They typically consist of a knitted wire mesh, a series of veins or even cyclone tubes.
- Is the design capacity large enough to handle a liquid slug without causing a high-level shut down?
- Does the pressure rating that match or exceed the pipes and equipment that will be connected to the KOD?
Liquid level control and monitoring are important design features of any KOD. Several engineered controls are built into each KOD required in many jurisdictions (AER, Directive 60).
- Visual Level indicators, usually a visual float or gauge.
- High Level Shut Down, triggering a high-level alarm, a facility block and hold or even a shutdown. They depend on the site level conditions.
Material selection is critical for each site. Many sites will contain sour gases or high saline liquids that can impact the performance and lifespan of the KOD. It is essential to confirm the material types used in the manufacturing of your KOD are rated appropriately.
Local jurisdictions may require additional features or design elements.
Types of KOD
There are many types and designs of KOD’s available suitable for many different applications.
- Fuel Gas Scrubbers
- Non-Code Vessels (<14.9psi rated)
- Code Vessels (<15 psi rated, ASME)
- Tanks
- Below Ground KOD
It is important to design for the application at hand and the environmental conditions that will be encountered. In many applications, like pneumatic discharge, a small KOD will be suitable as liquids are not anticipated to be encountered. However, other applications have a high risk of encountering liquids and may require large elaborate KOD’s.
It is best to consult with a design engineer of equipment manufacturer when planning a project.