Catalytic Heaters with Class 1/ Div 1 Wiring

  • Our explosion proof CCI Catadyne Radiant Heaters with our wiring packages are approved for use in Class 1/ Div 1 (hazardous) areas (Canada)
  • Mounted inside of the EnviroVault has the most efficient heat transfer for both single and double wall tanks as heat transfers directly through the vault wall into the fluid
  • Freeze protects entire tank contents and provides heat for internal valves and instrumentation
  • CCI catalytic heaters do not produce NOx or CO emissions in any measurable amount

Cata-Dyne Operational Information

The thermostat for the temperature controller has an adjustable bypass. When the thermostat is in the low fire mode (closed), the bypass is active. For example a WX model 24