Waste Gas Combustors

C-Series – Emission Rx Enclosed Waste Gas Combustor

The Emission Rx is a leading equipment provider for emission mitigation technologies in the North America Oil and Gas Industry. The C-series Enclosed Combustors have been developed to provide all the performance and advantages of a traditional incinerator at the price point of a flare. Meeting close spacing requirements in most locations, the C-Ceries Combustors provide easy install without the need to expand your site footprint.

Model No.
C 12-12
Size
Diameter x Height (ft)
1' x 12'
Capacity
(MMBTU/hr)
0.25
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
0.17 [6]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
Model No.
C 12-22
Size
Diameter x Height (ft)
1' x 22'
Capacity
(MMBTU/hr)
0.5
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
0.34 [12]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
Model No.
C 24-14
Size
Diameter x Height (ft)
2' x 12'
Capacity
(MMBTU/hr)
0.8
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
0.5 [17]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
Model No.
C 24-24
Size
Diameter x Height (ft)
2' x 22'
Capacity
(MMBTU/hr)
1.6
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
1 [35]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
Model No.
C 36-18
Size
Diameter x Height (ft)
3' x 18'
Capacity
(MMBTU/hr)
1.9
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
1.3 [46]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
Model No.
C 36-28
Size
Diameter x Height (ft)
3' x 28'
Capacity
(MMBTU/hr)
3.9
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
2.6 [92]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls

* Based on methane’s auto ignition temperature setting the temperature limit(combustor exit) of 580C

E Series – Emission Rx Enclosed Waste Gas Combustor

Emission Rx is a leading equipment provider for emission mitigation technologies in the North America Oil and Gas Industry. The E-Series Enclosed Combustors have been developed to handle greater volumes of waste gas. Using a unique cooling mechanism, the E-Series Enclosed Combustor are easily able to maintain a shell and exit temperature that meets close spacing requirements at high volumes of waste gas.

Model No.
E 24-12 (HP/LP)
Size
Diameter x Height (ft)
24"/12" x 12'
Capacity
(MMBTU/hr)
0.3
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
0.2[17]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Easy Operator Controls
Model No.
E 36-12 (HP/LP)
Size
Diameter x Height (ft)
36"/24" x 12'
Capacity
(MMBTU/hr)
1
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
0.7[25]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Easy Operator Controls
Model No.
E 48-12 (HP/LP)
Size
Diameter x Height (ft)
48"/36" x 12'
Capacity
(MMBTU/hr)
2.4
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
1.6[57]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Easy Operator Controls
Model No.
E 60-12 (HP/LP)
Size
Diameter x Height (ft)
60"/48" x 12'
Capacity
(MMBTU/hr)
3.7
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
2.5[88]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Easy Operator Controls
Model No.
E 72-12 (HP/LP)
Size
Diameter x Height (ft)
72"/53" x 12'
Capacity
(MMBTU/hr)
5
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
3.5[106]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Easy Operator Controls
Model No.
E 96-12 (HP/LP)
Size
Diameter x Height (ft)
96"/72" x 12'
Capacity
(MMBTU/hr)
7.4
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
5[175]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Easy Operator Controls
Model No.
E 96-24 (HP)
Size
Diameter x Height (ft)
96"/72" x 24'
Capacity
(MMBTU/hr)
15
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
10 [352]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Easy Operator Controls
Model No.
E 120-24 (HP)
Size
Diameter x Height (ft)
120"/80" x 24'
Capacity
(MMBTU/hr)
30
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
20[710]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Easy Operator Controls

**Please contact us for custom waste gas volumes greater than identified in the above table

(HP/LP) High-Pressure/Low-Pressure. High-Pressure is considered anything >1psi and Low-Pressure is anything <1psi

Low-Pressure applications can have a reduced capacity. Please contact for more information.

EF Series – Emission Rx Enclosed Waste Gas Flare

The EF-Series Enclosed Flares have been developed to ensure a good clean burn, protect against flame outages during strong winds, eliminate the view of flame and provide higher capacity burning of waste gas on oil and gas sites.

Model No.
EF 24-14
Size
Diameter x Height (ft)
2' x 14'
Capacity
(MMBTU/hr)
1.9
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
1.25 [44]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
Model No.
EF 24-25
Size
Diameter x Height (ft)
2' x 25'
Capacity
(MMBTU/hr)
3.7
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
2.5 [88]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
Model No.
EF 36-14
Size
Diameter x Height (ft)
3' x 14'
Capacity
(MMBTU/hr)
4
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
2.7 [95]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
Model No.
EF 36-24
Size
Diameter x Height (ft)
3' x 24'
Capacity
(MMBTU/hr)
8.2
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
5.5 [194]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls
Model No.
EF 48-24
Size
Diameter x Height (ft)
4' x 24'
Capacity
(MMBTU/hr)
15
Methane Equivalent Flow Rate
(e3m3/d [mscf/d])
10 [353]
Electrical
12V / 24V
Close Spacing Eligible
(10 Meters)
Self Supporting
(Concrete Base)
Exit Temperature Monitoring
Integrated Slug Catcher
Optional HLSD for Slug Catcher
Easy Operator Controls

Safe

Controlled burn environment

Reliable

Designed for continuous operation in harsh environments

Affordable

Designed for continuous operation in harsh environments

Small Footprint

Meets close spacing requirements

Simple Controls

Simple controls prevent unwanted compliance and operation issues

Free Standing

No guy wires needed