C-Series - Emission Rx Enclosed Waste Gas Combustor

The Emission Rx is a leading equipment provider for emission mitigation technologies in the North America Oil and Gas Industry. The C-series Enclosed Combustors have been developed to provide all the performance and advantages of a traditional incinerator at the price point of a flare. Meeting close spacing requirements in most locations, the C-Ceries Combustors provide easy install without the need to expand your site footprint.
Model No. Size Capacity Methane Equivalent Flow Rate Electrical Close Spacing Eligible Self Supporting Exit Temperature Monitoring Integrated Slug Catcher Optional HLSD for Slug Catcher Easy Operator Controls
Diameter x Height (ft) (MMBTU/hr) (e3m3/d [mscf/d]) (10 Meters) (Concrete Base)
C 12-12 1’ x 12’ 0.25 0.17 [6] 12V / 120V
C 12-22 1’ x 22’ 0.5 0.34 [12] 12V / 120V
C 24-14 2’ x 12’ 0.8 0.5 [17] 12V / 120V
C 24-24 2’ x 22’ 1.6 1 [35] 12V / 120V
C 36-18 3’ x 18’ 1.9 1.3 [46] 12V / 120V
C 36-28 3’ x 28’ 3.9 2.6 [92] 12V / 120V

* Based on methane's auto ignition temperature setting the temperature limit(combustor exit) of 580C

E Series - Emission Rx Enclosed Waste Gas Combustor

Emission Rx is a leading equipment provider for emission mitigation technologies in the North America Oil and Gas Industry. The E-Series Enclosed Combustors have been developed to handle greater volumes of waste gas. Using a unique cooling mechanism, the E-Series Enclosed Combustor are easily able to maintain a shell and exit temperature that meets close spacing requirements at high volumes of waste gas.
Model No. Size Capacity Methane Equivalent Flow Rate Electrical Close Spacing Eligible Self Supporting Exit Temperature Monitoring Integrated Slug Catcher Optional HLSD for Slug Catcher Easy Operator Controls
Diameter x Height (ft) (MMBTU/hr) (e3m3/d [mscf/d]) (10 Meters) (Concrete Base)
E 24-10 24'/12' x 10' 0.3 0.2[17] 12V / 120V No No
E 26-12 36'/24' x 12' 1 0.7[25] 12V / 120V No No
E 48-12 48'/36' x 12' 2.4 1.6[57] 12V / 120V No No
E 72-12 72'/48' x 12' 4.5 3[106] 12V / 120V No No
E 96-12 96'/72' x 12' 7.4 5[175] 12V / 120V No No
E 120-18 120'/80' x 18' 15 10[355] 12V / 120V No No

**Please contact us for custom waste gas volumes greater then identified in the above table

EF Series - Emission Rx Enclosed Waste Gas Flare

The EF-Series Enclosed Flares have been developed to ensure a good clean burn, protect against flame outages during strong winds, eliminate the view of flame and provide higher capacity burning of waste gas on oil and gas sites.
Model No. Size Capacity Methane Equivalent Flow Rate Electrical Close Spacing Eligible Self Supporting Exit Temperature Monitoring Integrated Slug Catcher Optional HLSD for Slug Catcher Easy Operator Controls
Diameter x Height (ft) (MMBTU/hr) (e3m3/d [mscf/d]) (10 Meters) (Concrete Base)
EF 24-14 2' x 14' 1.9 1.25 [44] 12V / 120V No No
EF 24-25 2' x 25' 3.7 2.5 [88] 12V / 120V No No
EF 36-14 3' x 14' 4 2.7 [95] 12V / 120V No No
EF 36-24 3' x 24' 8.2 5.5 [194] 12V / 120V No No
EF 48-24 4' x 24' 15 10 [353] 12V / 120V No No